TRANSIT BUS INTERNATIONAL

Component Description: FUEL SYSTEM, OTHER:STORAGE:TANK ASSEMBLY:PRESSURE RELIEF DEVICES

Defect Summary

UPON EXPOSURE TO IMPURITIES IN THE NATURAL GAS FUEL IN COLD WEATHER, AN INTERNAL O-RING ON THESE DEVICES CAN BLISTER DURING DECOMPRESSION AFTER "FAST-FILL" REFUELING RESULTING IN SEAL LEAKAGE.

Consequence Summary

INTERNAL DAMAGE TO THE O-RING SEAL COULD CAUSE ARELEASE OF CNG. IF CNG WERE RELEASED TO THE ENVIRONMENT AND AN IGNITION SOURCE WERE PRESENT, A FIRE COULD OCCUR.

Corrective Summary

MIRADA IS CONDUCTING THE OWNER NOTIFICATION AND REMEDY FOR THIS CAMPAIGN. DEALERS WILL REPLACE RECALLED UNITS WITH NEW DEVICES THAT ARE NOT SUSCEPTIBLE TO O-RING DAMAGE FROM NON-METHANE COMPONENTS OF THE GAS SUPPLY WHEN THE DEVICES ARE DEVELOPED.


Made between 8/1/1993 and 7/1/1994

Potential Number of Units Affected: 94

Date Owner Notified by Mfr:

Recall Initiator: Office of Defects Investigation

NHTSA Campaign Number: 95E005003